LKG 610

Display:

3 1/2 Digit LCD Display

Measurement Range:

Resistance: 0 - 1999 milliOhms Leakage Current: 0 - 1999 microAmp
Instrument Current: 0 - 19.99 Amps

Accuracy:

Resistance: +/- 2% +/- 1 LSD Leakage: +/- 1% of FS DC to 1 KHz +/- 1 LSD +/- 2% of FS 1 KHz to 100 KHz +/- 4% of FS 100 kHz to 1 MHz
Instrument Current: +/- 2% +/- 1 LSD

Power Requirements:

110 VAC 50 - 60 Hz, 20 Amp or 220 VAC 10 Amp maximum rated for the test outlet and 0.1 Amps rated for the unit.

Ambient Temperature:

Operating Range: 59 to 95 degrees F (15 to 35 degrees C)
Storage Temperature: 0 to 122 degrees F ( -18 to 50 degrees C)

Relative Humidity:

90% (max) at temperatures

Calibrated Test Points:

Reference Ground: 1 Ohm Leakage: 200 microAmp

 

General

Size:

8.0" x4.5" x 2.0" (20.3 x 11.4 x 5.0 cm)

Weight:

2.5 lbs (1.1 kg)

Controls:

12 Push Button Function Keys - Open / Closed, Neutral Switch Normal / Off / Reverse Polarity Switch, Momentary Ground Open Switch, 10 Universal Snap / Post ECG Connectors Test Load Selector Switch

 

It’s frustrating having multiple devices that only have singular functions. The LKG 610 Electrical Safety Analyzer is a single device with multiple possibilities. The instrument was designed with versatility at the forefront, and it can test any piece of electrically operated patient care equipment. This full-featured analyzer is microprocessor controlled, and it has a complete compliment of ten leads.

In addition to its high adaptability to any electrical patient care equipment, the LKG 610 also provides several critical measurements; this includes line voltage, outlet polarity, device current, earth leakage current, chassis resistance, and case leakage current. As a bonus, it also performs lead ISO tests and point-to-point measurements.

All tests are quickly performed by selecting the appropriate test function key. Measurement results are displayed on the large LCD screen with measurement units clearly indicated by an LED. Large switches change the polarity, open and close neutral, and lift the ground. Ten universal lead connectors accept both snaps and any size posts.

Calibrated test points are built in to ensure consistent and reliable performance of your equipment. Either AAMI or IEC 601-1 test loads may be selected. The receptacle is fused with an accessible 20A fuse and the tester itself is fused internally.

Reduce the numbers of devices you need to learn to operate with the LKG 610’s ideal combination of features.

FEATURES

  • Fast, accurate, portable, and easy-to-use
  • Large LCD Display
  • Accessible line fuse
  • Calibrated test points
  • Selectable test loads
  • 15 and 20 amp capabilities
  • Point-to-point cable
  • Uses any test cable
  • 10 lead universal connector
  • Complies with both AAMI and IEC 601-1 test loads
  • Soft carrying case and red resistance test cables included
  • LED unit of measure indicator

 

  • Product Code: 610
  • Availability: In Stock